Sustainable construction through improved durability : (Record no. 100663)

MARC details
000 -LEADER
fixed length control field 01994nam a22002417a 4500
003 - CONTROL NUMBER IDENTIFIER
control field OSt
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20261104133207.0
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 261104s2026 |||||||| |||| 00| 0 eng d
050 ## - LIBRARY OF CONGRESS CALL NUMBER
Classification number T ENG
Item number A46 2026
100 1# - MAIN ENTRY--PERSONAL NAME
Personal name Almanzor, Jeremae A.
245 10 - TITLE STATEMENT
Title Sustainable construction through improved durability :
Remainder of title curing methods in high-performance concrete /
Statement of responsibility, etc. Jeremae A. Almanzor, Eisenhowel D. Ariola, Aldwin N. Bonde, and Mathew Jose C. Oblevias.
264 ## - PRODUCTION, PUBLICATION, DISTRIBUTION, MANUFACTURE, AND COPYRIGHT NOTICE
Place of production, publication, distribution, manufacture EAC Cavite :
Name of producer, publisher, distributor, manufacturer School of Engineering,
Date of production, publication, distribution, manufacture, or copyright notice 2026.
300 ## - PHYSICAL DESCRIPTION
Extent ix, 76 pages ;
Dimensions 28 cm.
336 ## - CONTENT TYPE
Source rdacontent
Content type term text
337 ## - MEDIA TYPE
Source rdamedia
Media type term unmediated
338 ## - CARRIER TYPE
Source rdacarrier
Carrier type term volume
504 ## - BIBLIOGRAPHY, ETC. NOTE
Bibliography, etc Includes bibliographical references
520 ## - SUMMARY, ETC.
Summary, etc. This study evaluates the effectiveness of different curing methods on the compressive strength and water absorption of 62 MPa High-Performance Concrete (HPC). Using an experimental research design, 54 concrete specimens were tested across three curing regimes: Water Curing (Group A), Plastic Membrane Curing (Group B), and Curing Compound (Group C). Data analysis was conducted using descriptive statistics, graphical trend analysis, and percentage difference analysis to monitor the strength development at 7, 14, and 28 days. Results revealed that while membrane-based methods (Groups B and C) showed satisfactory early-age strength, only Water Curing (Group A) successfully achieved the target design strength, reaching a final average of 62.47 MPa. The trend analysis showed a significant deceleration in strength gain for the alternative methods after 14 days, with the curing compound showing a 13.77% strength reduction compared to the control group. The findings conclude that continuous external moisture is critical for the full hydration and structural integrity of high-strength concrete mixes.
700 1# - ADDED ENTRY--PERSONAL NAME
Relator code author
Personal name Ariola, Eisenhowel D.
700 1# - ADDED ENTRY--PERSONAL NAME
Relator code author
Personal name Bonde, Aldwin N.
700 1# - ADDED ENTRY--PERSONAL NAME
Relator code author
Personal name Oblevias, Mathew Jose C.
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Source of classification or shelving scheme Library of Congress Classification
Suppress in OPAC No
Koha item type THESIS
Call number prefix EAC Cavite-Thesis Section
Holdings
Withdrawn status Lost status Source of classification or shelving scheme Damaged status Not for loan Home library Current library Shelving location Date acquired Total Checkouts Full call number Barcode Date last seen Price effective from Koha item type
    Library of Congress Classification     EAC Library Cavite EAC Library Cavite EAC Cavite-Thesis Section 11/04/2026   T ENG A46 2026 ML-TH2862 11/04/2026 11/04/2026 THESIS